High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: FM radio station
FM broadcasts are transmitted at high frequencies and do not bend to follow the
earth's surface. Because of this, FM broadcasts generally begin to fade at short
distances from the station. Also, FM signals are easily affected by buildings, mountains,
or other obstructions. These can resu ...
Kia Niro 2017 (DE HEV) Service Manual: Hybrid Power Control Unit (HPCU) Components and components location
Components
1. Hybrid Control Unit(HCU) [HPCU]
2. Inverter [HPCU]
3. Low Voltage DC/DC Converter (LDC) [HPCU]
4. High voltage connector (↔ High voltage battery system assembly)
5. High voltage connector (↔ Hybrid drive motor assembly)