| Description |
Built into the Power Relay Assembly (PRA), the Pre-Charge Resistor protects the high voltage circuit by limiting the current while the inverter capacitor is being charged.

|
1. High Voltage Power Terminal (-) 2. High Voltage Power Terminal (+) 3. Battery Current Sensor 4. Inverter Power Terminal (-) 5. Inverter Power Terminal (+) 6. Pre-Charge Resistor |
7. Main Relay (+) 8. Pre-Charge Relay 9. Main Relay (-) 10. Power Relay Assembly Connector (Battery current sensor signal input) 11. Power Relay Assembly Connector (Main relay control) |
Pre-Charge Resistor Specifications
Pre-Charge Resistor Schematic diagramsKia Niro 2017 (DE HEV) Service Manual: Description and operating principle
Description and Operation
Wireless Power Charger
System
During ACC or IG ON, battery voltage is supplied to the wireless power charger
system to transmit an output of 5 W to mobile phone.
Mobile phones certified with the wireless charging standard WPC (Qi 1.1.2) or
equipped wit ...
Kia Niro 2017 (DE HEV) Service Manual: Idler Repair procedures
Removal and Installation
1.
Remove the drive belt.
(Refer to Drive Belt System - "Drive Belt")
2.
Remove the idler (A).
Tightening torque :
39.2 - 49.0 N·m (4.0 - 5.0 kgf·m, 28.9 - 36.2 lb·ft)
...