| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) in the direction of arrow.
|
| 4. |
Unfasten the lever (A) in the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro (DE HEV) Owners Manual: Anti-lock brake system (ABS)
WARNING
ABS (or ESC) will not prevent accidents due to improper or dangerous driving
maneuvers. Even though vehicle control is improved during emergency braking, always
maintain a safe distance between you and objects ahead. Vehicle speeds should always
be reduced during extreme road conditio ...
Kia Niro 2017 (DE HEV) Service Manual: Main Relay (+) / (-) Description and operation
Description
Main Relay is divided into the positive (+) relay and negative (-) relay. It
is integrated into the Power Relay Assembly (PRA) and connects the power supply
line and ground line between the high voltage battery and the inverter in accordance
with the BMS ECU control si ...