High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: Bulb replacement precaution
Please prepare bulbs with appropriate standards in case of emergencies. Refer
to “Bulb Wattage” in chapter 9.
When changing bulbs and sorts, first turn off the engine at a safe place, firmly
apply the side brake and take out the battery's negative (-) terminal.
WARNING - Working on the ...
Kia Niro (DE HEV) Owners Manual: Light bulb position (Rear)
■ Rear combination lamp - Type A
■ Rear combination lamp - Type B
■ Back up lamp
■ License plate lamp
■ High mounted stop lamp
(1) Stop/tail lamp(Bulb type)
(2) Tail lamp(Bulb type)
(3) Rear fog lamp(LED type)
(4) Rear turn signal lamp
(5) Stop/tail lamp(LED type)
(6) B ...