High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: START/RUN
Not illuminated
To start the engine, depress the brake pedal and press the engine start/stop
button with the shift lever in the P (Park) or the N (Neutral) position. For your
safety, start the engine with the shift lever in the P (Park) position.
✽ NOTICE
If you press the engine start/sto ...
Kia Niro 2017 (DE HEV) Service Manual: Reservoir Tank Repair procedures
Removal and Installation
1.
Drain the coolant.
(Refer to Cooling System - "Coolant")
2.
Disconnect the radiator reservoir hose (A).
3.
Disconnect the reservoir hose (B).
4.
Remove ...