| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) to the direction of arrow.
|
| 4. |
Unfasten the lever (A) to the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
General informationKia Niro 2017 (DE HEV) Service Manual: Battery Temperature Sensor Specifications
Specification
[Air Inlet]
Temperature
Resistance (kΩ)
°C
°F
-50
-58
314.9 - 344.6
-40
-40
181.1 - 196.0
-30
-22 ...
Kia Niro 2017 (DE HEV) Service Manual: Passenger Airbag (PAB) Module Repair procedures
Removal
1.
Disconnect the battery negative terminal, and wait for at least three
minutes before beginning to work.
2.
Remove the glove box assembly.
(Refer to Body (Interior and Exterior) - "Glove box housing")
...