| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) to the direction of arrow.
|
| 4. |
Unfasten the lever (A) to the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
General informationKia Niro 2017 (DE HEV) Service Manual: Brake/Clutch Fluid Repair procedures
Inspection
Check the brake fluid level in the brake fluid reservoir. The level should be
between “MIN” and “MAX” marks on the side of the reservoir.
Use only hydraulic brake fluid conforming to DOT 3 or DOT 4 specification.
Check the brake system for any leakage if th ...
Kia Niro 2017 (DE HEV) Service Manual: Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the blower motor connector (A).
4.
...