High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: High voltage shut-off procedures
High Voltage Shut-off Procedures
•
Be sure to read and follow the “General Safety Information and
Caution” before doing any work related with the high voltage system.
Failure t ...
Kia Niro (DE HEV) Owners Manual: In case of an emergency while driving
If the engine stalls at a crossroad or crossing
• If the engine stalls at a crossroad or crossing, set the shift lever in the
N (Neutral) position and then push the vehicle to a safe place.
If you have a flat tire while driving
If a tire goes flat while you are driving: