High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: If the engine overheats
If your temperature gauge indicates overheating, you will experience a loss of
power, or hear loud pinging or knocking, the engine is probably too hot. If this
happens, you should:
1.Pull off the road and stop as soon as it is safe to do so.
2.Place the shift lever in P (dual clutch transmissi ...
Kia Niro 2017 (DE HEV) Service Manual: Battery Pack Assembly Specifications
Specification
Battery Pack Assembly
[General Specification]
Item
Specification
Remarks
Number of Cells
16 Cells × 4 Modules [64 Cell]
1 Cell = 3.75 V
Type
LiPB (Lithium ion P ...