Kia Niro: Engine Control System / CVVT Oil Control Valve (OCV) Repair procedures

Kia Niro 2017 (DE HEV) Service Manual / Engine Control/Fuel System / Engine Control System / CVVT Oil Control Valve (OCV) Repair procedures

Inspection
1.

Switch "OFF" the ignition.

2.

Disconnect the OCV connector.

3.

Measure resistance between the OCV terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: 9.4 ~ 10.4 Ω [20°C(68°F)]

Removal
[CVVT Oil Control Valve (Exhaust)]
1.

Switch "OFF" the ignition and disconnect the negative (-) battery terminal.

2.

OCV extension wiring connector (A).

3.

Release the wiring mounting bracket (B) after loosening the mounting bolt.

4.

Remove the mounting bolt (A), and then remove oil control valve & extension wiring (B) from the engine.

CVVT oil control valve mounting bolt :

9.8 - 11.8 N·m (1.0 - 1.2 kgf·m, 7.2 - 8.7 lb·ft)

5.

Disconnect the oil control valve (A) from the extension wiring (B).

Installation
  
•

Install the component to the specified torque.

•

Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

•

Apply engine oil to the valve O-ring.

1.

Install in the reverse order of removal.

CVVT Oil Control Valve (OCV) Schematic diagrams
Circuit Diagram Harness Connector OCV [B1/EX] ...

Fuel Pressure Control Valve (FPCV) Specifications
Specification Item Specification Coil Resistance (Ω) 0.52 ± 5 % [20°C(68°F)] Rated Voltage (V) 6 ...

Other information:

Kia Niro (DE HEV) Owners Manual: Tires and wheels (For europe)
✽ NOTICE We recommend that when replacing tires, use the same originally supplied with the vehicles. If not, that affects driving performance. When driving in high altitude grades, it is natural for the atmospheric pressure to decrease. Therefore, please check the tire pressure and a ...

Kia Niro 2017 (DE HEV) Service Manual: Pre-Charge Relay Description and operation
Description Built into the Power Relay Assembly (PRA), the Pre-Charge Relay starts to charge the capacitor of the inverter soon after ignition "ON", then it goes out when the capacitor has been fully charged. 1. High Voltage Power Terminal (-) 2. Hig ...