Kia Niro: Heating, Ventilation and Air Conditioning / Specifications

Specification

Air Conditioner

Item
Specification
Compressor
Type
HES27 (Electric Scroll)
Communication type
CAN communication
Oil type & Capacity
POE Oil, 130 ± 10cc (4.58 ± 0.35oz.)
Motor type
BLDC
Rated voltage
270V
Operation voltage
190 - 320V
Expansion valve
Type
Block type
Refrigerant
Type
R-134a, R-1234yf
Capacity
550 ± 25 g (19.4 ± 0.88 oz.)

Blower Unit

Item
Specification
Fresh and recirculation
Operating method
Actuator
Blower
Type
Sirocco pan
Speed step
Auto + 8 speed (Automatic)
Speed control
PWM blower module (Auto)
Air filter
Type
Particle filter

Heater and Evaporator Unit

Item
Specification
Heater
Type
Pin & tube type
Heating capacity
4,560 - 4,800 kcal/hr (5.3 - 5.58 kw)
Mode operating method
Actuator
Temperature operating method
Actuator
Evaporator
Temperature control type
Evaporator temperature sensor
A/C ON/OFF [°C(°F)]
Blower 1 - 4 speed
ON: 3.0 ± 0.5°C(37.4 ± 0.9°F),
OFF: 1.5 ± 0.5°C(34.7 ± 0.9°F)
Blower 5 - 6 speed
ON: 2.5 ± 0.5°C(36.5 ± 0.9°F),
OFF: 1.0 ± 0.5°C(33.8 ± 0.9°F)
Blower 7 - 8 speed
ON: 2.1 ± 0.5°C(35.8 ± 0.9°F),
OFF: 0.6 ± 0.5°C(33.1 ± 0.9°F)

Tightening Torques
Items
N·m
kgf·m
lb·ft
Compressor - Mounting bolts
20.0 - 32.95
2.04 - 3.36
14.75 - 24.30
Compressor - Bracket bolts
21.6 - 32.4
2.2 - 3.3
6.5 - 10.1
Condenser - Discharge hose
7.8 - 11.8
0.8 - 1.2
5.8 - 8.7
Condenser - Liquid tube
Compressor - Discharge hose
7.8 - 11.8
0.8 - 1.2
6.5 - 10.1
Compressor - Suction hose
Expansion valve - Evaporator
7.8 - 11.8
0.8 - 1.2
6.5 - 10.1

High voltage shut-off procedures
High Voltage Shut-off Procedures    • Be sure to read and follow the “General Safety Informat ...

Troubleshooting
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air f ...

Other information:

Kia Niro 2017 (DE HEV) Service Manual: Description and operation
Description The Hybrid Power Control Unit (HPCU) uses various semiconductors that are supplied with high voltage, hence generating more heat than engine combustion devices. Overheating can decrease the efficiency of control devices, restrict proper operation and melt semiconductor ...

Kia Niro (DE HEV) Owners Manual: Jump starting procedure
1.Make sure the booster battery is 12-volt and that its negative terminal is grounded. 2.If the booster battery is in another vehicle, do not allow the vehicles come in contact. 3.Turn off all unnecessary electrical loads. 4.Connect the jumper cables in the exact sequence shown in the illustr ...

© 2016-2020 www.kniro.net