High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Center Pillar Trim Components and components location
Component Location
1. Center pillar lower trim
2. Center pillar upper trim
...
Kia Niro 2017 (DE HEV) Service Manual: Inspection mode procedures
Procedure for entering engine
forced activation mode
If the engine needs to be run constantly while the vehicle is stopped to inspect
emission gas or perform maintenance on the vehicle, follow the below procedure to
enter forced engine activation mode.
1.
Place ...