Removal |
|
|
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the gear knob & boots (A) pull both of it up.
|
3. |
Remove the console upper cover (A) by using a remover.
|
4. |
Disconnect the console upper cover connectors (A).
|
5. |
Remove the console front tray (A) after loosening the mounting screws.
|
6. |
Disconnect the console front tray connectors (A).
|
7. |
Remove the wireless charging pad (A).
|
8. |
Disconnect the wireless power charging unit connector (A).
|
9. |
Remove the wireless power charging unit (B) by pressing the fixing hooks (A).
|
Installation |
1. |
Install the wireless power charging unit. |
2. |
Connect the wireless power charging unit connector. |
3. |
Install the wireless charging pad. |
4. |
Connect the console front tray connectors. |
5. |
Install the console front tray. |
6. |
Connect the console upper cover connectors. |
7. |
Install the console upper cover. |
8. |
Install the gear knob & boots. |
9. |
Connect the negative (-) battery terminal. |
[Diagnosis With KDS/GDS] |
1. |
The body electrical system can be more quickly diagnosed for troubles by using the vehicle diagnostic system (KDS/GDS). KDS/GDS provides the following information.
|
2. |
To diagnose the vehicle by using the diagnostic equipment, select "vehicle model" and "wireless power charger system" to be inspected. |
3. |
To inquire the current status of input/output values, select the "Sensor Data" menu The input/output values of the sensors corresponding to the selected module can be checked.
|
4. |
To perform forced operation of the selected module input, select "Actuation Test".
|
5. |
To inquire the cause of trouble for each module by self diagnosis, select 'Diagnostic Trouble Code'.
|
Kia Niro 2017 (DE HEV) Service Manual: Heated Oxygen Sensor (HO2S) Schematic diagrams
Circuit Diagram
Harness Connector
[Bank 1 / Sensor 1]
[Bank 1 / Sensor 2]
...
Kia Niro (DE HEV) Owners Manual: Technical Data (18 inch tire)
System voltage: DC 12 V
Working voltage: DC 10 - 15 V
Amperage rating: MAX. 15A ± 1A (at DC 12V operation)
Suitable for use at temperatures: -30 ~ +70°C (-22 ~ +158°F)
Max. working pressure: 6 bar (87 psi)
Size
Compressor: 168 x 150 x 68 mm (6.6 x 5.9 x 2.7 in.)
Sealant bottle: 104 x 85 ø ...