High Voltage Shut-off Procedures |
|
High voltage components include: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor, etc. |
1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
2. |
Remove the safety plug cover (A) under the rear seat.
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: To convert to cruise control mode
“Smart Cruise Control or Cruise Control”
The driver may choose to only use the cruise control mode (speed control function)
by doing as follows:
1. Turn the smart cruise control system on (the cruise indicator light will be
on but the system will not be activated).
2. Push the distance to ...
Kia Niro 2017 (DE HEV) Service Manual: Electric Water Pump(EWP) Components and components location
Components Location
1. Eletric water pump (EWP)
...