High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Knock Sensor (KS) Repair procedures
Removal
1.
Switch "OFF" the ignition and disconnect the negative (-) battery terminal.
2.
Remove the intake manifold. (Refer to Engine Mechanical System - “Intanke
Manifold”)
3.
Remove the installat ...
Kia Niro 2017 (DE HEV) Service Manual: Hybrid Control Unit (HCU) Schematic diagrams
HCU Terminal And Input/Output
Signal
Terminal Function
Connector [C133-S]
Pin No.
Description
Connected to
1
HCU ground
Chassis ground
2
HCU ground
...