| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
| 2. |
Remove the safety plug cover (A) under the rear seat.
|
| 3. |
Unfasten the hook (A) in the direction of the arrow.
|
| 4. |
Unfasten the lever (A) in the direction of the arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro 2017 (DE HEV) Service Manual: Wireless Power Charging Unit Repair procedures
Removal
•
Handling wireless charging system parts by wet hands may cause
electric shock.
•
Put on gloves to protect your hands.
...
Kia Niro 2017 (DE HEV) Service Manual: Specifications
Specifications
Items
Specification
Hood
Type
Rear hinged, gas lifter type
Front Door
Construction
Front hinged, frame door construction
Regulator system
...