| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
| 2. |
Remove the safety plug cover (A) under the rear seat.
|
| 3. |
Unfasten the hook (A) in the direction of the arrow.
|
| 4. |
Unfasten the lever (A) in the direction of the arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro 2017 (DE HEV) Service Manual: Intake Actuator Repair procedures
Inspection
1.
Switch "OFF" the ignition.
2.
Disconnect the intake actuator connector.
3.
Verify that the intake actuator operates to the fresh position when connecting
12V to terminal 3 and grounding termin ...
Kia Niro 2017 (DE HEV) Service Manual: Components and components location
Component Location
1. Engine
2. Hybrid Drive Motor Assembly
3. Hybrid Starter Generator (HSG)
4. Transaxle
5. High Voltage Battery System Assembly
6. Power Cable
...