| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) in the direction of arrow.
|
| 4. |
Unfasten the lever (A) in the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro 2017 (DE HEV) Service Manual: General safety information and caution
Safety Precaution
Precautions to take before servicing
high voltage system
Hybrid vehicles have high voltage batteries. Incorrect handling
of high voltage sy ...
Kia Niro 2017 (DE HEV) Service Manual: TPMS Receiver Repair procedures
Removal
1.
Disconnect the battery negative cable.
2.
Remove the glove box.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the blower motor connector (A).
4.
Disconnect ...