| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) in the direction of arrow.
|
| 4. |
Unfasten the lever (A) in the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro (DE HEV) Owners Manual: Checking the coolant level
WARNING Removing radiator cap
Never attempt to remove the radiator cap while the engine is operating
or hot. Doing so might lead to cooling system and engine damage. Also, hot coolant
or steam could cause serious personal injury.
Turn the engine off and wait until it cools down. Use ex ...