High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: Emergency towing
■ Front
■ Rear
If towing is necessary, we recommend you to have it done by an authorized Kia
dealer or a commercial tow truck service.
If towing service is not available in an emergency, your vehicle may be temporarily
towed using a cable or chain secured to the emergency towing hook ...
Kia Niro 2017 (DE HEV) Service Manual: Components and components location
Component Location
1. Driver power window switch
2. Assist power window switch
3 . Integrated Gateway & Power control Module (IGPM)
4 . Door lock knob
5 . Tailgate actuator
6. Door latch module
7 . Door lock/unlock switch
8 . Rear ...