| High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
| 1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
| 2. |
Remove the safety plug cover (A) under the rear seat..
|
| 3. |
Unfasten the hook (A) to the direction of arrow.
|
| 4. |
Unfasten the lever (A) to the direction of arrow.
|
| 5. |
Remove the safety plug (A).
|
| 6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
| 7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
General safety information and caution
SpecificationsKia Niro 2017 (DE HEV) Service Manual: Repair procedures
Removal
•
Be sure to read and follow the “General Safety Information and
Caution” before doing any work related with the high voltage system.
Failure to follow the safety instr ...
Kia Niro (DE HEV) Owners Manual: Outside (fresh) air position
With the outside (fresh) air position selected, air enters the vehicle from outside
and is heated or cooled according to the function selected.
✽ NOTICE
Prolonged operation of the heater in the recirculated air position (without