Description |
Integrated into the HPCU, the Low Voltage DC/DC Converter charges the auxiliary battery as a substitute for the generator by converting high voltage (DC 270V) from the high voltage battery into low voltage (DC 12V).
Kia Niro 2017 (DE HEV) Service Manual: Specifications
Specification
Hybrid Control System
Hybrid Power Control
Unit (HPCU)
Item
Specification
Operating Voltage (V)
204 - 275.2
Operating Frequency (Hz)
Max. 826
LDC Output V ...
Kia Niro 2017 (DE HEV) Service Manual: Description and operation
Description
System Overview
The System offers the following features:
–
Changing the state of engine ignition and power by using the start button.
–
Controlling external relays for ACC / IGN1 / IGN2 terminal switching
and STARTER, w ...