High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: Do not lie down
To reduce the chance of injuries in the event of an accident and to achieve maximum
effectiveness of the restraint system, all passengers should be sitting up and the
front and rear seats should be in an upright position when the vehicle is moving.
A seat belt cannot provide proper protection ...
Kia Niro 2017 (DE HEV) Service Manual: Repair procedures
Diagnosis With KDS/GDS
1.
BSD system defects can be quickly diagnosed with the KDS/GDS. GDS operates
actuator quickly to monitor, input/output value and self diagnosis.
2.
Connect the cable of KDS/GDS to the data link connector in driver side ...