High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Repair procedures
Inspection
1.
After disconnecting the vapor hose from the PCV valve, remove the PCV
valve.
2.
Reconnect the PCV valve to the vapor hose.
3.
Run the engine at idle, then put a finger over the open end of the PCV
v ...
Kia Niro 2017 (DE HEV) Service Manual: Floor Console Assembly Components and components location
Component Location
1. Floor console assembly
...