High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: Smart key
To remove the mechanical key, press and hold the release button (1) and remove
the mechanical key (2).
To reinstall the mechanical key, put the key into the hole and push it until
a click sound is heard.
WARNING - Ignition key (smart key)
Leaving children unattended in a vehicle with the igni ...
Kia Niro 2017 (DE HEV) Service Manual: External AMP Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad center lower panel.
(Refer to Body - "Crash Pad Center Panel")
3.
Disconnect the external amplifier connectors (A).
...