High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Description and operation
Description
BSD is a system that uses two magnetic wave radar sensors attached on the rear
panel to measure the distance from the vehicle in the back and senses and sets off
(visual and auditory) alarms for any vehicle coming into the blind spot.
–
Blind Spot ...
Kia Niro (DE HEV) Owners Manual: Distance to empty
■ Type A
■ Type B
Distance To Empty
The distance to empty is the estimated distance the vehicle can be driven
with the remaining fuel.
- Distance range: 1~9,999 km or 1~9,999 mi.
If the estimated distance is below 1 km (1 mi.), the trip computer will
display “---” as dist ...